CFGZJ - PLY-TILE 700 COATING PART B, 043088

  • MSDS: CFGZJ
  • Manufacturer: M A BRUDER AND SONS INC
  • Product Name: PLY-TILE 700 COATING PART B, 043088
  • National Stock Number: 8010-00N076821
Product Identification

Product ID:PLY-TILE 700 COATING PART B, 043088
MSDS Date:04/14/1988
FSC:8010
NIIN:00N076821
MSDS Number: CFGZJ

Responsible Party
M A BRUDER & SONS INC
600 REED RD
BROOMALL, PA 19008
US

Emergency Phone: 215-353-5100

Info Phone: 215-853-2051

Cage: 85519

Contractor
M A BRUDER & SONS INC
600 BROOMALL, PA 19008 US

Telephone: 610-353-5100;610-359-3635

Cage: 85519

Ingredients

1.0%

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 19-25%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM


SOLVENT NAPHTHA (PETROLEUM), LIGHT AROMATIC; (AROMATIC

CAS: 64742-95-6

RTECS: WF3400000

Fraction By Weight: 3-5%

OSHA PEL N/K

ACGIH TLV: N/K


ISOBUTYRIC ACID, ISOBUTYL ESTER; (ISOBUTYL ISOBUTYRATE).

CAS: 97-85-8

RTECS: NQ5250000

Fraction By Weight: 13-17%

OSHA PEL N/K

ACGIH TLV: N/K


POLYESTER RESIN

CAS: 109909-27-5

Fraction By Weight: <3%

OSHA PEL N/K

ACGIH TLV: N/K


HAZARD. SYMPTOMS MAY NOT BE IMMEDIATELY APPARENT.

RTECS: 9999999ZZ


RAGS/WASTE CONTAINING OIL BASED PAINT/VARNISH

RTECS: 9999999ZZ


AND MAY IGNITE SPONTANEOUSLY AND SHOULD BE PLACED IN

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: CAN CAUSE ANESTH RXN.
POSS ACUTE NERV SYS DEPRESS/IRRIT OF RESP TRACT CHARACTERIZED BY
HDCH, DIZZ, STAGGERING GAIT, CONFUSION, UNCON & COMA. INTENTIONAL
MISUSE BY DELIBERATELY CONCENTRAT ING & INHALING CONTENTS MAY BE
HARMFUL/FATAL. RPTS HAVE ASSOC RPTD & PRLNG OCCUP OVEREXP TO SOLVS
W/ (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: PERM BRAIN & NERV SYS DMG. EYES/SKIN:
PRIMARY IRRIT. CHRONIC INHAL & SKIN/EYE CONT: EFTS OF EXCESS,
CHRONIC EXPOS HAVE NOT BEEN FULLY INVESTIGATED. RPTD HNDLG/USE MAY
PRESENT ADDITIONAL HAZA RDS. EXERCISE DUE CARE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP
WARM AND QUIET. CALL MD. EYES: FLUSH IMMEDIATELY WITH LARGE AMOUNTS
OF WATER AT LEAST 15 MINUTES. CONSULT MD FOR SPECIAL MEDICAL
TREATMENT. SK IN: WASH AFFECTED AREA WITH SOAP AND WATER. REMOVE
CONTAMINATED CLOTHING. CONSULT MD. INGESTION: CALL MD IMMEDIATELY .

Fire Fighting

Flash Point Method:SCC
Flash Point:93.0F,33.9C
Lower Limits:SEE INGS
Extinguishing Media:NFPA CLASSIFIES BURNING LIQS TO BE CLASS B FIRES.
THEREFORE, ANY APPRVD CLASS B FIRE EXTING/EXTING AGENT MAY BE(SUP
DAT)
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZZ ARE
PREF. WATER MAY BE USED TO COOL CLSD (SUP DAT)
Unusual Fire/Explosion Hazard:FLAM. KEEP CONTRS TIGHTLY CLSD. ISOLATE
FROM HEAT, ELEC EQUIP, SPKS & FLAME. VAPS MAY CAUSE FLASH FIRE.
CLSD CONTRS MAY EXPLODE WHEN EXPOSED TO EXTREME(SUP DAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAME, HOT
SURFACES AND ELECTRICAL, STATIC SPARKS). VENTILATE AREA AND AVOID
BREATHING VAPORS. CONTAIN AND REMOVE WITH INERT ABSORBENT MATERIAL
USING NON-SPARKING TOOLS .
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE IN SUN/ABOVE 120F. OSHA
STOR CATEGORY: STORE LGE QTYS IN BLDGS DESIGNED FOR STOR OF
FLAMM/COMBUST LIQS. DO NOT TAKE INTERNALLY.
Other Precautions:DO NOT WELD/FLAME CUT W/OUT PROPER VENT TO INSURE
AREA IS FREE OF FLAMM VAPS. DO NOT CUT, PUNCTURE/WELD ON/NEAR
CONTR. ENTRANCE INTO CLSD STOR TANKS: USE APPROP NIOSH APPRVD
RESP/AIR LINE FOR POSS EXP OS TO SOLV/CHEM FUMES. (ING 6)

Exposure Controls

Respiratory Protection:NIOSH APPROVED CHEMICAL MECHANICAL FILTER
RESPIRATOR DESIGNED TO REMOVE A COMBINATION OF PARTICULATE AND
VAPORS (NIOSH TC 23C OR EQUIVALENT).
Ventilation:ALL APPLICATION AREAS SHOULD BE VENTILATED I/A/W OSHA
REGULATION 29 CFR 1910 DURING USE & UNTIL AREA IS FREE OF VAPORS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . USE PROTECTIVE SKIN CREAM.
Work Hygienic Practices:WEAR CLEAN UNCONTAMINATED CLOTHING.
Supplemental Safety and Health
EXTING MEDIA: USED FOR FIRE FIGHTING PURPOSES (E.G., CARBON DIOXIDE,
DRY CHEM & FOAM). FIRE FIGHT PROC: CONTRS TO PVNT PRESS BUILD-UP &
POSS AUTO IGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT. EXPLO HAZ: H
EAT. APPLICATION TO HOT SURF REQUIRES SPECIAL PREC. DURING EMER
CNDTNS, OVEREXP TO DECOMP PRODS MAY CAUSE A HLTH (ING 5)

Chemical Properties

Boiling Pt:B.P. Text:>241F,>116C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.10-1.13
Evaporation Rate & Reference:SLOWER THAN ETHYL ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Percent Volatiles by Volume:58-60

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS OR BASES AND SELECTED AMINES.
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS AND FLAME.
Hazardous Decomposition Products:SMOKE, ACRID FUMES, CARBON MONOXIDE
AND/OR CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.